{"id":1101,"date":"2014-07-07T05:29:22","date_gmt":"2014-07-07T10:29:22","guid":{"rendered":"https:\/\/mcguirereport.mcguireclan.org\/?p=1101"},"modified":"2014-07-07T05:47:08","modified_gmt":"2014-07-07T10:47:08","slug":"20140630-monday-voltage-regulator","status":"publish","type":"post","link":"https:\/\/mcguirereport.mcguireclan.org\/?p=1101","title":{"rendered":"2014\/06\/30 &#8212; Monday &#8212; Voltage Regulator"},"content":{"rendered":"<p>Joel and Jim worked night shift this weekend and had today off,\u00a0 so I hitched a ride with Paul.<\/p>\n<p>Mike ordered a replacement regulator from E-bay for the standby diesel power plant.\u00a0 Until it arrives and without a working regulator, there will be no broadcasts in the event of a power failure.\u00a0 With this prospect and since Jim and Joel were not here to work on connecting the antenna switches, I decided to see if there was any possibility of repairing the failed regulator.<\/p>\n<div id=\"attachment_1177\" style=\"width: 622px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/mcguirereport.mcguireclan.org\/wp-content\/uploads\/2014\/07\/140630-VoltageRegulator.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1177\" class=\"size-full wp-image-1177\" src=\"https:\/\/mcguirereport.mcguireclan.org\/wp-content\/uploads\/2014\/07\/140630-VoltageRegulator.jpg\" alt=\"Someone had already begun to chip away at the potting material, but I figured the most likely failure might be in the higher current circuits, probably on the right side of the voltage regulator.\" width=\"612\" height=\"816\" srcset=\"https:\/\/mcguirereport.mcguireclan.org\/wp-content\/uploads\/2014\/07\/140630-VoltageRegulator.jpg 612w, https:\/\/mcguirereport.mcguireclan.org\/wp-content\/uploads\/2014\/07\/140630-VoltageRegulator-225x300.jpg 225w\" sizes=\"auto, (max-width: 612px) 100vw, 612px\" \/><\/a><p id=\"caption-attachment-1177\" class=\"wp-caption-text\">Someone had already begun to chip away at the potting material around what looked like the sensing circuitry, but I figured the most likely failure might be in the higher current circuits, probably on the right side of the voltage regulator.\u00a0 After removing the first layer, an extra heat sink began to appear.<\/p><\/div>\n<div id=\"attachment_1179\" style=\"width: 826px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/mcguirereport.mcguireclan.org\/wp-content\/uploads\/2014\/07\/140630-VoltageRegulator2.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1179\" class=\"size-full wp-image-1179\" src=\"https:\/\/mcguirereport.mcguireclan.org\/wp-content\/uploads\/2014\/07\/140630-VoltageRegulator2.jpg\" alt=\"After shifting into 'archeological dig' mode, the first power device was exposed.\" width=\"816\" height=\"612\" srcset=\"https:\/\/mcguirereport.mcguireclan.org\/wp-content\/uploads\/2014\/07\/140630-VoltageRegulator2.jpg 816w, https:\/\/mcguirereport.mcguireclan.org\/wp-content\/uploads\/2014\/07\/140630-VoltageRegulator2-300x225.jpg 300w\" sizes=\"auto, (max-width: 816px) 100vw, 816px\" \/><\/a><p id=\"caption-attachment-1179\" class=\"wp-caption-text\">After shifting into &#8216;archeological dig&#8217; mode, the first power device was finally exposed.<\/p><\/div>\n<div id=\"attachment_1180\" style=\"width: 826px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/mcguirereport.mcguireclan.org\/wp-content\/uploads\/2014\/07\/140630-VoltageRegulator3.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1180\" class=\"size-full wp-image-1180\" src=\"https:\/\/mcguirereport.mcguireclan.org\/wp-content\/uploads\/2014\/07\/140630-VoltageRegulator3.jpg\" alt=\"Eventually, three power devices were 'unearthed' that were attached to the heat sink.  The two on the left tested OK, but the rectifier bridge on the right had a dead short on one of its four diodes.\" width=\"816\" height=\"612\" srcset=\"https:\/\/mcguirereport.mcguireclan.org\/wp-content\/uploads\/2014\/07\/140630-VoltageRegulator3.jpg 816w, https:\/\/mcguirereport.mcguireclan.org\/wp-content\/uploads\/2014\/07\/140630-VoltageRegulator3-300x225.jpg 300w\" sizes=\"auto, (max-width: 816px) 100vw, 816px\" \/><\/a><p id=\"caption-attachment-1180\" class=\"wp-caption-text\">Eventually, three power devices were &#8216;unearthed&#8217; that were all attached to the extra heat sink. The two on the left tested OK, but the rectifier bridge on the right had a dead short on one of its four diodes.<\/p><\/div>\n<div id=\"attachment_1181\" style=\"width: 826px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/mcguirereport.mcguireclan.org\/wp-content\/uploads\/2014\/07\/140630-VoltageRegulator4.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1181\" class=\"size-full wp-image-1181\" src=\"https:\/\/mcguirereport.mcguireclan.org\/wp-content\/uploads\/2014\/07\/140630-VoltageRegulator4.jpg\" alt=\"The faulty bridge was successfully removed and replaced with four discrete diodes.\" width=\"816\" height=\"612\" srcset=\"https:\/\/mcguirereport.mcguireclan.org\/wp-content\/uploads\/2014\/07\/140630-VoltageRegulator4.jpg 816w, https:\/\/mcguirereport.mcguireclan.org\/wp-content\/uploads\/2014\/07\/140630-VoltageRegulator4-300x225.jpg 300w\" sizes=\"auto, (max-width: 816px) 100vw, 816px\" \/><\/a><p id=\"caption-attachment-1181\" class=\"wp-caption-text\">The faulty bridge was successfully removed and replaced with four discrete diodes.<\/p><\/div>\n<p>After the &#8216;repair&#8217; was completed, we had just enough time to install and test the regulator in the standby power plant.\u00a0 Unfortunately, the regulator&#8217;s 5 amp fuse blew immediately!\u00a0 Now when we checked, the diodes were OK, but the other two power devices had both failed.\u00a0 Our attempt was not successful, but at least we tried!<\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Joel and Jim worked night shift this weekend and had today off,\u00a0 so I hitched a ride with Paul. Mike ordered a replacement regulator from E-bay for the standby diesel power plant.\u00a0 Until it arrives and without a working regulator, there will be no broadcasts in the event of a power failure.\u00a0 With this prospect [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":1177,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_s2mail":"yes","footnotes":""},"categories":[15],"tags":[],"class_list":["post-1101","post","type-post","status-publish","format-standard","hentry","category-guam-2014"],"_links":{"self":[{"href":"https:\/\/mcguirereport.mcguireclan.org\/index.php?rest_route=\/wp\/v2\/posts\/1101","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/mcguirereport.mcguireclan.org\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/mcguirereport.mcguireclan.org\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/mcguirereport.mcguireclan.org\/index.php?rest_route=\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/mcguirereport.mcguireclan.org\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=1101"}],"version-history":[{"count":3,"href":"https:\/\/mcguirereport.mcguireclan.org\/index.php?rest_route=\/wp\/v2\/posts\/1101\/revisions"}],"predecessor-version":[{"id":1182,"href":"https:\/\/mcguirereport.mcguireclan.org\/index.php?rest_route=\/wp\/v2\/posts\/1101\/revisions\/1182"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/mcguirereport.mcguireclan.org\/index.php?rest_route=\/wp\/v2\/media\/1177"}],"wp:attachment":[{"href":"https:\/\/mcguirereport.mcguireclan.org\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=1101"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/mcguirereport.mcguireclan.org\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=1101"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/mcguirereport.mcguireclan.org\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=1101"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}